Changing minimum paths, round trip time, other remote connection options

You can change remote connection options that affect how the system runs your copy operations. These are:

To change remote connection options

  1. In Hitachi Command Suite:

  1. On the Resources tab, expand the Storage Systems tree, right-click the target storage system and click Remote Connections.

In Storage Navigator

  1. Click Storage Systems, and then expand the Storage Systems tree.

  1. In the Storage Systems tree, click Replication > Remote Connections.

  1. Click the Connections (To) tab, the select the remote connection whose options you want to change.

  1. In the Connections (To) tab, click Edit Remote Connection Options.

  1. In the Edit Remote Connection Options window, for Minimum Number of Paths, select the minimum number of paths between the remote and primary system.

  1. For RIO MIH Time, enter an interval in seconds that, if exceeded, causes the data-transfer operation to be reported as failed by the system. The range is from 10 to 100 seconds; 15 is the default.

  1. For Round Trip Time, enter a time limit for data copy from P-VOL to S-VOL. Range is 1-500 milliseconds.

  1. Click Finish.

  1. In the Confirm window, review the settings and enter a task name in the Task Name box.

  1. Click Apply to save your settings in the system.