Edit Mirror Options window

Use this window to change the mirror options.

Item

Description

Path Watch Time

Interval from the time a path becomes blocked to the time when the mirror is suspended.

Path Watch Time Transfer

Indicates whether to assign the master journal’s Path Watch Time value to the restore journal: Yes or No.

Copy Pace

Pace for copying data during initial copy: Slower is the default, Medium, Faster.

Transfer Speed

Data transfer line speed in Mbps (megabits per second): 10, 100, 256.

Delta Resync Failure

Processing that takes place in the event of delta resync operation failure.

  • Entire Copy: The entire P-VOL is copied to the S-VOL.

  • No Copy: No processing occurs. The S-VOL is not updated.

Delta Resync Failure cannot be set at the secondary site. Use Entire Copy if your journals are part of a multiple-journal configuration in a CCI consistency group.