show
Description
This subcommand outputs the following information to the standard output (for example, to the command prompt):
The period during which monitoring data was collected onto SVP (storing period).
The interval at which the monitoring data was collected (sampling interval).
Performance Monitor collects data between 1 and 15 days in SVP. The show subcommand displays the storing period of monitoring data. Note the following example:
Range From : 2006/10/01 01:00 - To: 2006/10/01 15:00 Interval : 1min.
If using the range subcommand, you can narrow down the data which you want to save. From is the starting time and To is the ending time. Interval shows the sampling interval. For example, if it is Interval 15min, monitoring data is collected every 15 minutes.
Storing periods output by the show subcommand are the same as the information displayed in the Monitoring Term area of the Monitor Performance window.
The monitoring term area

The login command must execute before the show subcommand executes.
Syntax
show
Outputs
The show subcommand displays the storing period and the sampling interval for the monitoring data. For example, the show subcommand outputs the following information:
Range From: 2006/10/01 01:00 - To: 2006/10/01 15:00 Interval: 1min.
From indicates the starting time for collecting monitoring data. To indicates the ending time for collecting monitoring data.
Interval indicates the interval at which the monitoring data was collected (sampling interval). For example, Interval 15min. indicates that monitoring data was collected at 15-minute intervals.