Edit Journal Options confirmation window

Item

Description

Journal ID

Journal identifier.

Journal Type (VSP G1000, G1500, and VSP F1500)

Journal copy type, UR or URMF.

Attribute

Master, Restore, or Initial (registered but no pair volumes assigned).

Number of Journal VOLs

Number of journal volumes registered in the journal.

Journal Capacity

Capacity of the journal volume registered in the journal. If two journal volumes are registered, the capacity of the reserve journal volume is subtracted from the total capacity.

Number of Data VOLs

Number of volumes associated with the journal.

(VSP G1000, G1500, and VSP F1500) If the journal uses multiple mirror IDs, volumes in mirrors with Hold, Holding, or Hold(Failure) status are not included.

(VSP Gx00 models and VSP Fx00 models) With the delta resync configuration, the number of data volumes registered to the journal of the mirrors not for delta resync is displayed. The number of volumes registered to the journal of the delta resync mirrors (whose status is Hold, Holding, or Hold(Failure)) is not displayed.

Data Capacity

Total capacity of all the associated volumes.

(VSP G1000, G1500, and VSP F1500) If the journal uses multiple mirror IDs, the capacity of volumes in mirrors with Hold, Holding, or Hold(Failure) status is not included.

(VSP Gx00 models and VSP Fx00 models) With the delta resync configuration, the number of data volumes registered to the journal of the mirrors not for delta resync is displayed. The number of volumes registered to the journal of the delta resync mirrors (whose status is Hold, Holding, or Hold(Failure)) is not displayed.

Inflow Control

Whether flow of update data to the journal volume is restricted by slowing the response to hosts.

Data Overflow Watch

Number of seconds the system will monitor write data to the journal volume when the journal volume is full (100%). A hyphen (-) displays if Inflow Control is disabled.

Cache Mode

Indicates whether journal data is stored in cache memory on the restore journal.

(VSP G1000, G1500, and VSP F1500)

  • Enable: Journal data is stored in cache memory. When the available cache memory becomes insufficient, the journal data is also stored in a journal volume.

  • Disable: Journal data is stored in a journal volume instead of cache memory.This setting is disabled in the master journal. However, this setting is enabled if you use the horctakeover command of CCI (for Universal Replicator) or the YKRESYNC REVERSE command of Business Continuity Manager (for Universal Replicator for Mainframe) to change the master journal to the restore journal.

Timer Type (VSP G1000, G1500, and VSP F1500)

URz only.

Type of clock used for consistency time. Must be the same for primary and secondary storage systems.