Splitting a UR pair

When you split a pair, write-data is no longer sent to the S-VOL and the pair is no longer synchronized. Splitting a pair or mirror gives you a point-in-time copy of the P-VOL.

Before you begin

The following additional information may be useful before beginning the procedure:

Procedure

  1. Open the Remote Replication window:

In Hitachi Command Suite:

  1. On the Resources tab, expand the Storage Systems tree.

  1. Right-click the target storage system, and click Remote Replication.

In Device Manager - Storage Navigator:

  1. In the Explorer pane, expand the Storage Systems tree.

  1. Expand the target storage system tree, expand Replication, and click Remote Replication.

  1. In the UR Pairs tab, select the pairs to be split and click Split Pairs.

  1. In the Split Pairs window, review the pairs to be split in the Selected Pairs table. To remove a pair from the table, select the pair and click Cancel.

  1. For Secondary Volume Write, specify whether data can be written to the S-VOL while it is split. Available only when performing the split operation from the pair’s primary storage system.

olh-note.gif In a 3DC configuration in which three UR sites are combined, host I/O write requests to the split pair's S-VOL might be rejected when the delta resync pair shares the split S-VOL, even if you split a pair with the Secondary Volume Write option enabled.

  1. Click Finish.

  1. In the Confirm window, review the settings, enter a task name, and then click Apply.