Changing remote connection options
You can change the following remote connection options that affect how copy operations are performed:
- Number of minimum paths for a pair. You can find detailed information in the planning section on minimum number of remote paths in the TrueCopy User Guide
- RIO MIH Time, which is the interval for data transfer to complete.
- Round trip time, which is the time limit for copying data to the S-VOL. For more information, see the planning section on round trip time in the TrueCopy User Guide for more information.
Procedure
-
Click Storage Systems, and then expand the Storage Systems tree.
-
In the Storage Systems tree, click .
-
Click the Connections (To) tab, and then select the remote connection whose options you want to change.
-
In the Connections (To) tab, click Edit Remote Connection Options.
-
In the Edit Remote Connection Options window, for Minimum Number of Paths, select the minimum number of paths between the secondary and primary system.
-
For RIO MIH Time, enter an interval in seconds that, if exceeded, causes the data-transfer operation to be reported as failed by the system. The range is 10-100 seconds, and the default is 15.
-
For Round Trip Time, enter a time limit for data copy from P-VOL to S-VOL in ms. The range is 1-500 ms, and the default is 1.
-
Click Finish.
-
In the Confirm window, review the settings and enter a task name in the Task Name box.
-
Click Apply to save your settings in the system.