Supported data path configurations
The data path can be configured using one of the following connection types. For a switch connection, you must set the port to Fabric on, Point-to-Point (F-port).
Direct connection
A direct connection (loop only) is a direct link between the primary and secondary arrays. NL-port (Node Loop) connections are supported for the data path and host-to-system path.
- Set the Fabric to OFF for the initiator port and the RCU target port.
- Set the topology to FC-AL.
Switch connection
Switch connections push data from the local switch through a Fibre Channel link across a WAN to the remote switch and Fibre Channel of the secondary storage system. F-port (point-to-point) and FL-port (loop) switch connections are supported.
- Set the Fabric to ON for the initiator port and the RCU target port.
- Set the topology to Point-to-Point.
Switches from some vendors, McData ED5000 for example, require an F-port.
Extender connection
Make sure that the extender supports remote I/O. Contact customer support for details.
- Set the Fabric to ON for the initiator port and the RCU target port.
- Set the topology to Point-to-Point.