Example of shredding data on flash drives
In this sample configuration, the flash drive capacity is 400 GB, the RAID configuration is 3D+1P, and the LDEV capacity is 440 GB.
Procedure
-
Calculate the number of shredding operations.
[(400 × 3) × 2] / 440 = 5.45 = six timesRound up the value (5.45) to the nearest whole number. You need to overwrite the data six times.
-
Define the shredding settings.
Refer to Defining shredding conditions, enter the dummy data 00 in the text box and add a row to the Data Pattern (User Setting) list (add rows for performing the shredding operation six times). -
Erase the volume data.
Refer to Defining shredding conditions and execute the shredding operation. -
Repeat steps 2 and 3 using the dummy data FF.
-
Repeat steps 2 and 3 using the dummy data 00.