Defining port attributes
Initiator and RCU target ports must be set up on the primary and secondary systems for TrueCopy command and data transfer.
Before you begin
- Storage Administrator (System Resource Management) is required.
- The number of hosts connected to a target port must be limited to 128 or fewer to avoid disconnection.
- See the topic on planning ports in the TrueCopy User Guide for information about target, initiator, and RCU target ports.
- If you are changing a target port to an initiator port, prepare the port for the change as follows:
- Confirm that the port is offline.
- Disconnect the port from the host.
- Remove all channel paths to the port.
- If you are changing a Fibre channel port
or iSCSI port from an initiator port to a target or RCU target port, prepare the port for the change as follows:
- Release all pairs using the ports.
- Delete the paths from the initiator port to the remote storage system.
- Disconnect the connection from the local storage system to the remote storage system. See Deleting remote connections.
Procedure
-
Click Storage Systems, and then expand the Storage Systems tree.
-
In the Storage Systems tree, click Ports/Host Groups/iSCSI Targets.
-
In the Ports/Host Groups/iSCSI Targets window, click the Ports tab, select the port to be changed, and click Edit Ports.
-
In the Edit Ports window, select a Port Attribute: Initiator or RCU Target.
For all other settings, see the Provisioning Guide for Open Systems. -
Click Finish.
-
In the Confirm window, review the settings and enter a task name in the Task Name box.
-
Click Apply to save your settings.