Copying all LU paths defined in an iSCSI target
Perform one of the following to display the tab.
For Command Suite:
On the Resource tab, expand the Storage Systems tree. On the target storage system, click Port / Host Group. Select the Host Groups / iSCSI Targets tab.
For Storage Navigator:
To display all iSCSI targets in the storage system, in the Storage Systems tree, click the Ports/Hosts Groups/ iSCSI Targets, select the Host Groups / iSCSI Targets tab.
To display iSCSI targets related to each port, in the Storage Systems tree, expand the Ports/Hosts Groups/ iSCSI Targets node, select each port. Select the iSCSI Targets tab.
Select the iSCSI target check box.
Display the Create Alternative LUN Paths window by performing one of the following:
Click More Actions and select Create Alternative LUN.
From the Actions menu, select Ports/Host Groups, iSCSI, then Create Alternative LUN Paths.
In the Create Alternative LUN Paths window, select the copy destination port from the Available Ports table, then click Add.
The selected ports appear in the Selected Ports table.
Click Finish.
In the Confirm window, confirm the settings, in Task Name type a unique name for this task or accept the default, then click Apply.
If Go to tasks window for status is checked, the Tasks window opens.