Errors when operating CCI (Dynamic Provisioning, SSB1: 0x2e31/0xb96d)
|
Error Code (SSB2) |
Error Contents |
Solutions |
|---|---|---|
|
0x2c3a |
The operation was rejected because the specified volume was being enabled for the attribute of the data direct mapping. |
Specify the volume in which the data direct mapping attribute is disabled. |
|
0x9100 |
The command cannot be executed because user authentication is not performed. |
Perform user authentication. |
|
0xb900/ 0xb901/ 0xaf28 |
Error occurred when increasing DP-VOL capacity operation. |
Ask the customer support to solve the problem. |
|
0xb902 |
The operation was rejected because the configuration was being changed by SVP or Device Manager - Storage Navigator, or because the DP-VOL capacity was going to be increased by another instance of the CCI. |
Increase the DP-VOL capacity after finishing operations on your storage system, such as the Virtual LUN operation or a maintenance operation. . |
|
0xaf22 |
The operation was rejected because the specified volume is placed online with the OS which does not support EAV (Extended Address Volume). |
Increase the DP-VOL capacity after the specified volume is placed online with the OS which supports EAV. |
|
0xaf24 |
The operation was rejected because the total DP-VOL capacity exceeded the pool reservation rate after the capacity was increased. |
Specify a capacity so that the pool reservation rate will not be exceeded. |
|
0xaf25 |
The operation to increase capacity cannot be performed on the specified DP-VOL. |
Check the emulation type of the specified DP-VOL. |
|
0xaf26 |
The operation was rejected because of a lack of cache management devices due to increased capacity. |
Specify a capacity so that the maximum number of cache management devices will not be exceeded. |
|
0xaf29 |
The operation was rejected because the specified volume was not a DP-VOL, |
Makes sure that the volume is a DP-VOL. |
|
0xaf2a |
The operation was rejected because the specified capacities are invalid or exceeded the value immediately below LDEV Capacity in the Expand Virtual Volumes window. |
To increase capacity, specify the correct capacity that does not exceed the value immediately below LDEV Capacity in the Expand Virtual Volumes window. |
|
0xaf2b |
The operation was rejected because the specified volume operation was not finished. |
Re-execute the operation after a brief interval. |
|
0xaf2c |
The operation was rejected because the control memory capacity is not enough to increase the specified capacity. |
Confirm the value immediately below LDEV Capacity in the Expand Virtual Volumes window. |
|
0xaf2e |
The operation was rejected because the specified DP-VOL was used by other software or was being formatted. |
Wait until formatting of the specified volume is finished, or see Using Dynamic Provisioning, Dynamic Tiering, or active flash with other VSP G200, G400, G600, G800 or VSP F400, F600, F800 products and confirm whether the DP-VOL is used with software in which that the DP-VOL capacity cannot be increased. |
|
0xaf2f |
The specified DP-VOL capacity cannot be expanded because the configuration of journal volumes is being changed. |
Re-execute the operation after the journal volume configuration is changed. |
|
0x0b2b |
The operation was rejected because the raidcom extend ldev command was executed with specifying the -cylinder option to the DP-VOL for the open-system. |
Re-execute the raidcom extend ldev command without specifying the -cylinder option. |