Performance monitoring or tier relocation conditions
The status of data collection, fixed monitoring, and tier relocation operations are described in the following table. The latest fixed monitoring information is referenced when tiers are relocated.
|
Monitoring information or execution conditions |
Status of data collection in progress |
Status of fixed monitoring information used in tier relocation |
Tier relocation operations |
Solutions |
|---|---|---|---|---|
|
Unallocated pages. |
Pages are not monitored. |
No monitoring information on pages. |
Tiers of the pages are not relocated. |
Unnecessary. After the pages are allocated, monitoring and relocation are performed automatically. |
|
Zero data is discarded during data monitoring. |
Monitoring on pages is reset. |
Only monitoring information on pages is invalid. |
Tiers of the pages are not relocated. |
Unnecessary. After the pages are allocated, monitoring and relocation are performed automatically. |
|
V-VOL settings do not allow tier relocation. |
Volume is monitored. |
Monitoring information on the volume is valid. |
If the tier relocation setting is being disabled at the performance monitoring finish time, tiers of the volume are not relocated. |
N/A |
|
When V-VOLs are deleted |
Volume is not monitored. |
Only monitoring information on the volume is invalid. |
Tier relocation of the volume is suspended. |
N/A |
|
When execution mode is changed to Manual from Auto or vice versa. |
Suspended. |
Monitoring information collected before suspension is valid. |
Suspended. |
Collect the monitoring information again if necessary.1 |
|
When the power switch is power ON or OFF. |
Monitoring is suspended by powering OFF and is not resumed even after powering ON.1 |
Monitoring information collected during the previous cycle is valid. |
Tier relocation is suspended by powering OFF and is resumed after powering ON. |
Collect the monitoring information again if necessary.1 |
|
The monitoring information of the volume is not collected at the present moment. In the next monitoring period, the monitoring information will be collected. |
Monitoring information is invalid and the volumes must be monitored. |
Tier relocation to volumes is suspended. |
Collect the monitoring information again if necessary.1 |
|
S-VOL of the following program products when the initial copy operation is performed:
|
Monitoring information is continuously collected, but the monitoring of the volumes is reset.2 |
No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid. |
Tier relocation to volumes is suspended. |
Collect the monitoring information again if necessary.1 |
|
Continued. |
Fixed monitoring information is invalid because the monitoring information has been discarded. If the monitoring mode is set to continuous mode, weighted data calculated by using the monitoring information in past periods is also discarded. |
Suspended. |
Relocate tiers again.1 |
|
When the pool-VOLs are deleted. |
Continued. |
Monitoring information is temporarily invalid. The monitoring information is calculated again after deleting pool-VOLs.4 |
Deleting the pool-VOL stops the tier relocation. The process resumes after the pool-VOL is deleted. |
N/A |
|
When a cache is blocked. |
Continued. |
No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid. |
Suspended. |
After recovering the faulty area, relocate tiers again.1 |
|
When an LDEV is blocked (Pool-VOL or V-VOL). |
Continued. |
No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid. |
Suspended. |
After recovering the faulty area, relocate tiers again.1 |
|
When the pool is almost full during relocation. |
Continued. |
No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid. |
Suspended. |
Add pool-VOLs, then collect monitoring information and relocate tiers again.1 |
|
When execution mode is Auto and the execution cycle ends during tier relocation. |
At the end time of execution cycle, data monitoring stops. |
The monitoring information collected before monitoring performance stops is valid. |
Suspended. |
Unnecessary. The relocation is performed automatically in the next cycle. |
|
When execution mode is Manual and 7 days elapse after monitoring starts. |
Suspended. |
The monitoring information collected before suspension is valid. |
Continued. |
Collect the monitoring information again if necessary.1 |
|
Notes:
|
||||