Unaffected S-VOL status and pair user tasks
The SI pair actions you can perform depend on the pair's status and the status of unaffected S-VOLs.
The following table shows the actoins you can perform based on the status of S-VOLs related to the P-VOL in other pairs.
|
Status of unaffected S-VOLs |
Pair action |
|||||
|---|---|---|---|---|---|---|
|
Create pairs |
Split pairs |
Resynchronize pairs (Normal Copy) |
Resynchronize pairs (Reverse Copy) |
Suspend pairs |
Delete pairs |
|
|
SMPL(PD) |
NO |
NO |
NO |
NO |
NO |
NO |
|
COPY(PD)/COPY |
YES |
YES |
YES |
NO |
YES |
YES |
|
PAIR |
YES |
YES |
YES |
NO |
YES |
YES |
|
COPY(SP)/COPY |
YES |
YES |
YES |
NO |
YES |
YES |
|
PSUS(SP)/PSUS |
YES |
YES |
YES |
NO |
YES |
YES |
|
PSUS |
YES |
YES |
YES |
YES |
YES |
YES |
|
COPY(RS)/COPY |
YES |
YES |
YES |
NO |
YES |
YES |
|
COPY(RS-R)/RCPY |
NO |
NO |
NO |
NO |
YES |
YES |
|
PSUE |
YES |
YES |
YES |
YES |
YES |
YES |