Changing the Fence Level

You can change the fence level for each pair.

For more information on fence levels, see the planning section on fence level options for I/O to the P-VOL after suspension in the TrueCopy User Guide.

Prerequisite information

Procedure

  1. Open the Remote Replication window.

In Hitachi Command Suite:

  1. On the Resources tab, expand the Storage Systems tree.

  1. Right-click the target storage system, and click Remote Replication.

In Storage Navigator:

  1. Click Storage Systems, and then expand the Storage Systems tree.

  1. In the Storage Systems tree, click Replication > Remote Replication.

  1. In the Remote Replication window, click the TC Pairs tab, and then select the pair whose options are to be changed.

  1. In the TC Pairs tab, click More Actions > Edit Pair Options.

  1. In the Edit Pair Options window, for Primary Volume Fence Level box, select the fence level for the pairs.

- Never: The P-VOL can always be written to.

- Data: The P-VOL cannot be written to.

- Status: The P-VOL cannot be written to only if the primary system is not able to change S-VOL status to PSUE.

  1. Click Finish.

  1. In the Confirm window, review the settings and enter a task name in the Task Name box.

  1. Click Apply to save your settings in the system.