3DC cascade configuration requirements and cautions
One VSP G800, VSP F800, or VSP G1000 is required at the each of the three sites of primary, intermediate, and secondary. When there is more than one storage system at each site, the 3DC cascade cannot be configured.
RAID Manager is recommended at all three sites.
Storage Navigator is required at all three sites.
The primary site requires the following:
Host application
TrueCopy
TC primary volume (P-VOL), the primary production volume
The TC P-VOL fence level (Primary Volume Fence Level) must be Secondary Volume Data.
The intermediate site requires the following:
TrueCopy
Universal Replicator
TC S-VOL, which is also the UR P-VOL
UR master journal
The secondary site requires the following:
Universal Replicator
UR S-VOL
UR restore journal
Differential data is used to resynchronize a suspended TC or UR pair.