Creating ShadowImage pairs

Creating an SI pair copies the P-VOL to the S-VOL.

olh-note.gif If you create an SI pair during WriteSame or Unmap command processing, the pair creation might fail. In this case, create the pair again after the WriteSame or Unmap command processing finishes.

Before you begin

For more information about S-VOL status, see Unaffected S-VOL status and pair tasks.

For more information about checking I/O performance, see the Command Suite User Guide.

Procedure

  1. In Command Suite:

  1. On the Resources tab, click Storage Systems, expand the storage system tree, right-click the target storage system, and then select Local Replication.

In Device Manager - Storage Navigator:

  1. In the Explorer pane, click Storage Systems, expand the storage system tree, and then click Replication > Local Replication.

  1. In the Local Replication window, select the SI Pairs tab.

  1. On the SI Pairs tab, click Create SI Pairs.

  1. In the Select Pair Configuration window, complete the following steps, and then click Next:

For more information about creating L1 and L2 pairs with different topologies, see Creating L1 and L2 pairs with different topologies.

Values:

- Non Split: The pair is not split.

olh-note.gif If you are simultaneously creating an L1 pair and an L2 pair, to prevent a failure and splitting the L2 pair before the pair is split (PSUS status), select Non Split.

- Quick Split (default): Splits the new pair, and then copies the data so that the S-VOL is immediately available for read and write I/O. The storage system copies the remaining differential data to the S-VOL in the background.

- Steady Split: Copies the differential data to the S-VOL, and then splits the new pair.

Values:

- Slower: Improved host server I/O performance but slower processing speed.

- Medium (default): Average processing speed and host server I/O performance.

- Faster: Faster processing speed but slower host server I/O performance.

olh-note.gif The pace you select affects processing speed and host server I/O performance.

  1. In the Select Primary Volumes window of the Create SI Pairs wizard, complete the following steps:

  1. Optional: Filter LDEVs by port ID, host group name, or iSCSI target alias.

  1. In the Available LDEVs table, select one or more LDEVs you want to be P-VOLs, and then click Add.

olh-note.gif Nondisruptive migration volumes do not appear in the Available LDEVs table.

Selected LDEVs are moved to the Selected LDEVs table.

  1. Click Next.

  1. In the Select Secondary Volumes window of the Create SI Pairs wizard, assign LDEVs as S-VOLs to the specified P-VOL LDEVs.

olh-note.gif Nondisruptive migration volumes do not appear in the Available LDEVs table.

After an S-VOL is selected, you can also perform the following optional steps:

The remaining number you have to select refers to the P-VOLs that do not have an assigned S-VOL, as seen in the Selected Pairs table.

a. Select the line for the LDEV in the Selected Pairs table.

b. Click Edit Mirror Units.

c. In the Edit Mirror Units dialog box, specify the S-VOL's L1 and L2 mirror unit numbers, and click OK.

The pair topology is modified.

For more information about changing a pair's topology, see Creating L1 and L2 pairs with different topologies.

The pair's topology is refined.

  1. Click Finish, and then confirm the settings.

  1. Accept the default task name or enter a unique name.

You can enter up to 32 letters, numbers, and symbols, except the following:

\ / : , ; * ? " < > |

  1. If you want to monitor the task after submitting it, select Go to tasks window for status.

  1. Click Apply to submit the task.

The SI pair is created and the status is PAIR.

Related concepts

Related tasks