Local Replication window

Use this window to perform the following tasks:

This window contains the following section and tabs:

Summary section

Item

Description

Number of Pairs

The number of pairs for each local replication software type.

Snapshot Estimated Manageable Capacity*

The estimated HTI pair capacity. The icon appears when the estimated capacity is less than:

  • VSP G1000 and G1500, and VSP F1500: 128 TB

  • VSP G200: 12 TB

  • VSP G400, G600, G800: 20 TB

For more information about snapshot estimated manageable capacity, see the Thin Image User Guide.

Number of Consistency Groups

The number of consistency groups (CTGs) that have a status other than Free, and the maximum number of CTGs allowed.

Number of Snapshot Groups

The number of snapshot groups that are in use, and the maximum number of snapshot groups allowed.

Number of Pair Tables

The number of pair tables in use, and the maximum number of pair tables allowed.

Values:

  • (VSP G1000, G1500, and VSP F1500) SI/SIMF/Volume Migration: SI, SI-MF, Volume Migration

  • (VSP Gx00 models and VSP Fx00 models) SI/Volume Migration: SI, Volume Migration

  • TI: HTI

Number of Differential Tables

The number of differential tables in use, and the maximum number of differential tables allowed.

Because differential tables are not used for all operations, the number of differential tables does not change when you execute the following operations:

  • Thin Image pair operations.

  • SI pair operations for a DP-VOL that exceeds 4 TB.

  • (VSP G1000, G1500, and VSP F1500) SI-MF pair operations for a DP-VOL that exceeds 262,668 cylinders.

*Snapshot Estimated Manageable Capacity is an estimation of Thin Image pair capacity that is calculated by subtracting shared memory used by Thin Image pools and Thin Image pairs from the shared memory capacity. Snapshot Estimated Manageable Capacity is only a reference estimation and does not guarantee that the space is available. The Snapshot Estimated Manageable Capacity value changes when Thin Image pool volumes or Thin Image pairs are added or deleted.

SI Pairs tab

This tab of the Local Replication window shows the SI/SI-MF pairs for which the P-VOLs or S-VOLs are allocated to you.

The following table describes the items on this tab.

Item

Description

Primary Volume

The P-VOL information.

Values:

  • LDEV ID: The P-VOL's LDEV identifier.

Click to open the LDEV Properties window, which contains additional information for the selected replica LDEV.

  • LDEV Name: The P-VOL's LDEV name.

  • Port ID: The P-VOL's port identifier.

SI only. For SI pairs with an undefined path, a blank is displayed.

  • Host Group Name / iSCSI Target Alias: The P-VOL's host group name and ID or iSCSI target alias and ID.

SI only. For SI pairs with an undefined path, a blank is displayed.

  • iSCSI Target Name: The P-VOL's iSCSI target name.

SI only. For SI pairs with an undefined path, a blank is displayed.

  • LUN ID: The P-VOL's LUN identifier.

SI only. . For SI pairs with an undefined path, a blank is displayed.

  • Provisioning Type*: The P-VOL's provisioning type, which can be one of the following:

  • Basic: Internal volume

  • DP: DP-VOL

  • External: External volume

  • (VSP G1000, G1500, and VSP F1500) External MF: Migration volume

  • (VSP G1000, G1500, and VSP F1500) Emulation Type*: The P-VOL's emulation type.

  • (VSP Gx00 models and VSP Fx00 models) Attribute*: The P-VOL's attribute.

  • Capacity*: The P-VOL's volume capacity.

  • CLPR*: The P-VOL's CLPR ID.

  • Encryption*: The P-VOL's encryption information.

  • Enabled: Encryption is enabled for the parity group to which the P-VOL's LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption enabled.

  • Disabled: Encryption is disabled for the parity group to which the P-VOL's LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption disabled.

  • Mixed: The pool to which the P-VOL's LDEV belongs contains both pool volumes for which encryption is enabled and ones for which encryption is disabled.

Note: Data encryption is not ensured in an LDEV with Mixed encryption status.

For DP-VOLs, the pool to which an LDEV belongs is an external volume or blocked.

For an external volume or migration volume, a hyphen (-) is displayed.

  • T10 PI*: The P-VOL's T10 PI attribute information.

  • Enabled: The P-VOL's T10 PI attribute is enabled.

  • Disabled: The P-VOL's T10 PI attribute is disabled.

(VSP G1000, G1500, and VSP F1500) For SI-MF pairs, a hyphen (-) is displayed.

  • Virtual Storage Machine*: The model type and serial number of the virtual storage machine to which the P-VOL belongs.

  • Virtual LDEV ID*: The identification number of the P-VOL's virtual LDEV. If no virtual LDEV ID is assigned, a blank is displayed.

  • Virtual Device Name*: The name of the P-VOL's virtual device, in a combined format of virtual emulation type, number of virtual LUSE volumes, and virtual CVS attribute. Each of these three items is displayed only if it is specified. If none of them are specified, a blank is displayed. "CVS" is displayed at the end of the device name, if the virtual CVS attribute is specified.

  • Virtual SSID*: The virtual SSID of the P-VOL. If no virtual SSID is specified, a blank is displayed.

Copy Type

The pair type.

Values:

  • SI-L1: SI L1

  • SI-L2: SI L2

  • (VSP G1000, G1500, and VSP F1500) SIMF: SI-MF

Snapshot Group

HTI only.

The snapshot group name.

If you have not assigned the pair to a snapshot group, a blank is displayed.

Status

The status of the pair.

For SI status descriptions, see Device Manager - Storage Navigator pair status names and descriptions.

For SI status descriptions, see the ShadowImage User Guide.

Secondary Volume

The S-VOL information.

Values:

  • LDEV ID: The S-VOL's LDEV identifier. Click the LDEV ID to open the LDEV Properties window, which contains additional information for the selected LDEV.

  • LDEV Name: The S-VOL's LDEV name

  • Port ID: The name of the S-VOL LUN path.

SI only.For SI pairs with an undefined path, a blank is displayed.

  • Port Name: The S-VOL's port name.

HTI only.

  • Host Group Name / iSCSI Target Alias: The S-VOL's host group name and ID or iSCSI target alias and ID.

SI only. For SI pairs with an undefined path, a blank is displayed.

  • iSCSI Target Name: The S-VOL's iSCSI target name.

SI only. For SI pairs with an undefined path, a blank is displayed.

  • LUN ID: The S-VOL's LUN identifier.

SI only. For SI pairs with an undefined path, a blank is displayed.

  • Provisioning Type*: The S-VOL's provisioning type, which can be one of the following:

  • Basic: Internal volume

  • DP: DP-VOL

  • External: External volume

  • (VSP G1000, G1500, and VSP F1500) Emulation Type*: The S-VOL's emulation type.

  • (VSP Gx00 models and VSP Fx00 models) Attribute*: The S-VOL's attribute.

  • Capacity*: The S-VOL's capacity

  • CLPR*: The S-VOL's CLPR ID

  • Encryption*: The S-VOL's encryption information.

  • Enabled: Encryption is enabled for the parity group to which the S-VOL's LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption enabled.

  • Disabled: Encryption is disabled for the parity group to which the S-VOL's LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption disabled.

  • Mixed: The pool to which the S-VOL's LDEV belongs contains both pool volumes for which encryption is enabled and ones for which encryption is disabled.

Note: Data encryption is not ensured in an LDEV with Mixed encryption status.

For DP-VOLs, the pool to which an LDEV belongs is an external volume or blocked.

For an external volume or migration volume, a hyphen (-) is displayed.

  • T10 PI*: The S-VOL's T10 PI attribute information.

  • Enabled: The S-VOL's T10 PI attribute is enabled.

  • Disabled: The S-VOL's T10 PI attribute is disabled.

  • Virtual Storage Machine*: The model type and serial number of the virtual storage machine to which the S-VOL belongs.

  • Virtual LDEV ID*: The identification number of the S-VOL's virtual LDEV. If no virtual LDEV ID is assigned, a blank is displayed.

  • Virtual Device Name*: The name of the S-VOL's virtual device, in a combined format of virtual emulation type, number of virtual LUSE volumes, and virtual CVS attribute. Each of these three items is displayed only if it is specified. If none of them are specified, a blank is displayed. "CVS" is displayed at the end of the device name, if the virtual CVS attribute is specified.

  • Virtual SSID*: The virtual SSID of the S-VOL. If no virtual SSID is specified, a blank is displayed.

Snapshot Date

HTI only.

The date and time the snapshot was acquired.

If you have not acquired a snapshot, a blank is displayed.

Pool Name (ID)

HTI only.

The pool name and identification number.

If you have not set a pool name, a blank is displayed.

Copy Pace*

The system option that determines the rate at which you want the storage system to copy data.

Values:

  • Slower: Improved host I/O performance but slower processing speed.

  • Medium: Average processing speed and host I/O performance.

  • Faster: Faster processing speed but slower host server I/O performance.

If you have not set a copy pace, a blank is displayed.

CTG ID*

The identifier of the consistency group to which the SI/SI pair is assigned.

Mirror Unit*

The mirror unit number.

Topology ID

The LDEV's topology identifier. This item shows the tier of a pair with the mirror unit, which is expressed in the following format:

LDEV ID of the volume (mirror units)

Example: 00.00.00 (MU0-MU1)

Create SI Pairs button

Click to open the Create SI Pairs wizard.

Create TI Pairs button (VSP Gx00 models and VSP Fx00 models)

Click to open the Create TI Pairs wizard.

Split Pairs button

Click to open the Split Pairs wizard.

Resync Pairs button

Click to open the Resync Pairs wizard.

More Actions

Click to show options.

Options:

  • View Pair Synchronization Rate: Click to open the View Pair Synchronization Rate window.

  • View Pair Properties: Click to open the View Pair Properties window.

  • Suspend Pairs: Click to open the Suspend Pairs window.

  • Delete Pairs: Click to open the Delete Pairs window.

  • Export: Click to open a dialog for downloading table information to a tab-separated values (TSV) file.

* These items are not shown in the table by default. You must add them using the Column Settings window.

For more information about how to add items to a table using this window, see the Hitachi Device Manager - Storage Navigator User Guide.

TI Root Volumes tab or TI Primary Volumes tab

Use this tab of the Local Replication window to view HTI pair information for local replication.

The following table describes the items on this tab.

Item

Description

LDEV ID

The P-VOL's LDEV identifier.

Click to open the LDEV Properties or TI Pairs window.

Use this window to search for P-VOL information.

LDEV Name

The P-VOL's LDEV name.

Port ID

The port name of the P-VOL LDEV's LUN path. For SI pairs with an undefined path, a blank is displayed.

Host Group Name / iSCSI Target Alias

The P-VOL's host group name and ID or iSCSI target alias and ID. For SI pairs with an undefined path, a blank is displayed.

iSCSI Target Name

The P-VOL's iSCSI target name. For SI pairs with an undefined path, a blank is displayed.

LUN ID

The LUN ID of the P-VOL LDEV's LUN path. For SI pairs with an undefined path, a blank is displayed.

Attribute* (VSP Gx00 models and VSP Fx00 models)

The P-VOL's attribute.

Capacity*

The P-VOL's capacity.

CLPR* (VSP Gx00 models and VSP Fx00 models)

The P-VOL's CLPR ID.

Encryption*

The P-VOL's encryption information.

  • Enabled: Encryption is enabled for the parity group to which the P-VOL's LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption enabled.

  • Disabled: Encryption is disabled for the parity group to which the P-VOL's LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption disabled.

  • Mixed: The pool to which the P-VOL's LDEV belongs contains both pool volumes for which encryption is enabled and ones for which encryption is disabled.

Note: Data encryption is not ensured in an LDEV with Mixed encryption status.

For DP-VOLs, the pool to which an LDEV belongs is an external volume or blocked.

For an external volume or migration volume, a hyphen (-) is displayed.

Pool Name (ID)*

The P-VOL's pool name and identifier.

Number of Snapshot Data

The number of P-VOL snapshot data.

Number of Pairs in PSUE status

The number of P-VOL pairs in PSUE status.

Cascade

(VSP G1000, G1500, and VSP F1500)

Indicates whether cascade pairs can be created.

Enabled: Cascade pairs can be created.

Disabled: Cascade pairs cannot be created.

T10 PI*

The P-VOL's T10 PI attribute information.

  • Enabled: The P-VOL's T10 PI attribute is enabled.

  • Disabled: The P-VOL's T10 PI attribute is disabled.

Virtual Storage Machine*

The Virtual Storage Machine information.

Values:

  • Model/Serial Number: The model type and serial number of the virtual storage machine to which the P-VOL belongs.

  • LDEV ID: The identification number of the P-VOL's virtual LDEV. If no virtual LDEV ID is assigned, a blank is displayed.

  • Device Name: The name of the P-VOL's virtual device, in a combined format of virtual emulation type, number of virtual LUSE volumes, and virtual CVS attribute. Each of these three items is displayed only if it is specified. If none of them are specified, a blank is displayed. "CVS" is displayed at the end of the device name, if the virtual CVS attribute is specified.

  • SSID: The virtual SSID of the P-VOL. If no virtual SSID is specified, a blank is displayed.

Create TI Pairs button

Click to open the Create TI Pairs wizard.

Operate TI Pairs button

Click to open the TI Pairs wizard.

View Pair Synchronization Rate button

Click to open the View Pair Synchronization Rate window.

More Actions

Click to show options.

Options:

  • View Pair Properties: Click to open the View Pair Properties window.

  • View LDEV Properties: Click to open the View LDEV Properties window.

  • Split Pairs: Click to open the Split Pairs window.

  • Resync Pairs: Click to open the Resync Pairs window.

  • Assign Secondary Volumes: Click to open the Assign Secondary Volumes window.

  • Remove Secondary Volumes: Click to open the Remove Secondary Volumes window.

  • Delete Pairs: Click to open the Delete Pairs window.

  • Export: Click to open a dialog for downloading table information to a tab-separated values (TSV) file.

* These items are not shown in the table by default. You must add them using the Column Settings window.

For more information about how to add items to a table using this window, see the Hitachi Device Manager - Storage Navigator User Guide.

Consistency Groups tab

Use this tab of the Local Replication window to perform the following tasks:

For more information about this tab, select In-System Replication to navigate to the desired software and information.

The following table describes the items on this tab of the Local Replication window.

Item

Description

CTG ID

The SI pair's CTG identification number.

Click to open the Consistency Group Properties window.

Status

The status.

Values:

  • SI Used: The CTG is being used by SI.

  • (VSP G1000, G1500, and VSP F1500) SIMF Used (RAID Manager): SI-MF is using the CTG, and you are using RAID Manager to manage the CTG.

  • (VSP G1000, G1500, and VSP F1500) SIMF Used (PPRC/BCM): SI-MF is using the CTG, and you are using Business Continuity Manager (BCM) or IBM PPRC to manage the CTG.

  • TI Used: HTI is using the CTG.

  • (VSP G1000, G1500, and VSP F1500)Mainframe Reserved: The CTG is reserved for use with BCM or IBM PPRC.

  • Free: The CTG is not being used and is not reserved.

  • (Changing...): The status is in the process of changing.

Number of Pairs

The number of pairs assigned to the CTG.

Reserve Mainframe CTGs button (VSP G1000, G1500, and VSP F1500)

Click to open the Reserve Mainframe CTGs window.

Release Reserved Mainframe CTGs button (VSP G1000, G1500, and VSP F1500)

Click to open the Release Reserved Mainframe CTGs window.

Export button

Click to open a dialog for downloading table information to a tab-separated values (TSV) file.

Snapshot Groups tab

This tab of the Local Replication window shows your snapshot groups.

The following table describes the items on this tab of the Local Replication window.

Item

Description

Snapshot Group

The snapshot group name.

Click to open the HTI pairs window.

Number of Pairs

The number of pairs currently used by the snapshot group.

Create TI Pairs button

Click to open the Create TI Pairs wizard.

Operate TI Pairs button

Click to open the TI Pairs wizard.

View Pair Synchronization Rate button

Click to open the View Pair Synchronization Rate window.

More Actions

Click to show options.

Options:

  • Split Pairs: Click to open the Split Pairs window.

  • Resync Pairs: Click to open the Resync Pairs window.

  • Assign Secondary Volumes: Click to open the Assign Secondary Volumes window.

  • Remove Secondary Volumes: Click to open the Remove Secondary Volumes window.

  • Delete Pairs: Click to open the Delete Pairs window.

  • Export: Click to open a dialog for downloading table information to a tab-separated values (TSV) file.