Edit Remote Connection Options window

Use this window to edit remote connection options, such as minimum paths and round trip time.

For complete information and instructions for TC or TCz, in Contents, click:

For complete UR or URz information, see the section on modifying data-transfer time threshold in the Universal Replicator User Guide or Universal Replicator for Mainframe User Guide.

Selected Remote Connection table

Item

Description

Minimum Number of Paths

Minimum number of remote paths.

  • TC and TCz: The range is from 1 to 8, and the default is 1.

  • UR and URz: The minimum number is set to 1, regardless of the number entered.

RIO MIH Time

Time limit between 10 and 100 seconds (default = 15) for the data-transfer operation to complete.

Round Trip Time

TC, TCz, and GAD only.

Time limit between 1 and 500 milliseconds for data copy from P-VOL to S-VOL (1 is the default).

FREEZE Option (VSP G1000, G1500, and VSP F1500)

TCz only.

Enables or disables support for the CGROUP (FREEZE/RUN) PPRC TSO command.

Displayed only when Connection Type is CU.