Select Primary Volumes window

Use this window of the Create SI Pairs wizard to select LDEVs that are P-VOLs.

This window contains the following tables:

The following table describes items in this window.

Item

Description

Use Primary Volumes of Snapshot Pairs

HTI only.

Indicates whether P-VOLs are used.

Values:

  • Yes: Only HTI P-VOL LDEVs are shown in the Available LDEVs table.

  • No: Only unpaired LDEVs are shown in the Available LDEVs table.

Use Primary Volumes of Thin Image Pairs

HTI only.

Selects the kind of volumes you want to show in the Available LDEVs table.

Values:

  • Yes: The LDEVs that are already used as P-VOLs are shown.

  • No (default): The LDEVs that are not used as P-VOLs are shown.

If you select No, you must select a pool

Selection Object (VSP Gx00 models and VSP Fx00 models)

Filters LDEVs in the Available LDEVs table according to port type.

Values:

  • Fibre

  • iSCSI

Port ID

SI and HTI only.

Filters LDEVs in the Available LDEVs table according to the port ID.

Default: Any

Host Group Name

SI and HTI only.

Filters LDEVs in the Available LDEVs table by the host group name. This item is displayed if you select a Fibre Channel port for Port ID.

Default: Any

iSCSI Target Alias

SI and HTI only.

Filters LDEVs in the Available LDEVs table by the iSCSI target alias. This item is displayed if you select an iSCSI port for Port ID.

Default: Any

Available LDEVs table

This table is displayed on the Select Primary Volumes window.

The following table describes the items in this table.

Item

Description

LDEV ID

The LDEV's identifier.

LDEV Name

The LDEV's name.

Port ID

SI and HTI only.

The port name of the LDEV's LUN path.

Host Group Name / iSCSI Target Alias

SI and HTI only.

The host group name and ID or iSCSI target alias and ID of the LDEV's LUN path.

iSCSI Target Name

SI and HTI only.

The iSCSI target name.

LUN ID

SI and HTI only.

The LUN identifier of the LDEV's LUN path.

Provisioning Type

The LDEV's provisioning type.

Values:

  • Basic: Internal volume

  • DP: DP-VOL

  • External: External volume

  • ALU: Volume with ALU attribute.

Attribute

SI and HTI only.

The LDEV's attribute.

Values:

  • ALU: Volume with ALU attribute.

  • SLU: Volume with SLU attribute.

  • Data Direct Mapping: Volume with Data Direct Mapping attribute.

  • (VSP Gx00 models and VSP Fx00 models) NAS Platform (User LU): NAS User LU.

If the attribute is not set, a hyphen (-) is displayed.

Emulation Type (VSP G1000, G1500, and VSP F1500)

SI and SIz only.

The LDEV's emulation type.

Capacity

The LDEV's capacity.

CLPR

The LDEV's CLPR ID.

Encryption

Encryption information.

  • Enabled: Encryption is enabled for the parity group to which the LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption enabled.

  • Disabled: Encryption is disabled for the parity group to which the LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption disabled.

  • Mixed: The pool to which the LDEV belongs contains both pool volumes for which encryption is enabled and ones for which encryption is disabled.

Note: Data encryption is not ensured in an LDEV with Mixed encryption status.

For DP-VOLs, the pool to which an LDEV belongs is an external volume or blocked.

For an external volume or migration volume, a hyphen (-) is displayed.

T10 PI (VSP Gx00 models and VSP Fx00 models)

The LDEV's T10 PI attribute.

  • Enabled: The T10 PI attribute is enabled.

  • Disabled: The T10 PI attribute is disabled.

Number of Secondary Volumes

The total number of S-VOLs assigned to the P-VOL. This value includes the volumes for pairs that you are creating, volumes in existing pairs. For an L1 pair, this value does not include the number of L2 S-VOLs.

Primary Volumes (VSP G1000, G1500, and VSP F1500)

HTI only.

The P-VOL information when the LDEV is used as a S-VOL for an existing pair.

Values:

  • LDEV ID: LDEV identifier

  • LDEV Name: LDEV name

  • Port ID: Port name of the LDEV's LUN path

  • Host Group Name: Host group name of the LDEV's LUN path

  • LUN ID: LUN ID of the LDEV's LUN path

  • Emulation Type: Volume's emulation type

  • Capacity: Volume's capacity

  • CLPR: The volume's CLPR ID.

Mirror Unit (VSP G1000, G1500, and VSP F1500)

HTI only.

The mirror unit number.

Pool Name (ID) (VSP G1000, G1500, and VSP F1500)

HTI only.

The pool name and identification number.

Select Pool button

HTI only.

Click to open the Select Pool window.

Note: This window does not open if you selected Yes for Use Primary Volumes of Snapshot Pairs.

Add button

Click to move the selected LDEVs from the Available LDEVs table to the Selected LDEVs table.

Remove button

Click to move the selected LDEVs from the Selected LDEVs table to the Available LDEVs table.

Selected LDEVs table

This table is displayed on the Select Primary Volumes window.

The following table describes the items in this table.

Item

Description

LDEV ID

The selected P-VOL's LDEV identifier.

LDEV Name

The selected P-VOL's LDEV name.

Port ID

SI and HTI only.

The port name of the LDEV's LUN path.

Host Group Name / iSCSI Target Alias

SI and HTI only.

The host group name and ID or iSCSI target alias and ID of the LDEV's LUN path.

iSCSI Target Name

SI and HTI only.

The iSCSI target name.

LUN ID

SI and HTI only.

The LUN identifier of the LDEV's LUN path.

Provisioning Type

The LDEV's provisioning type.

Values:

  • Basic: Internal volume

  • DP: DP-VOL

  • External: External volume

  • ALU: Volume with ALU attribute.

Attribute

SI and HTI only.

The LDEV's attribute.

Values:

  • ALU: Volume with ALU attribute.

  • SLU: Volume with SLU attribute.

  • Data Direct Mapping: Volume with Data Direct Mapping attribute.

  • (VSP Gx00 models and VSP Fx00 models) NAS Platform (User LU): NAS User LU.

If the attribute is not set, a hyphen (-) is displayed.

Emulation Type (VSP G1000, G1500, and VSP F1500)

SI and SIz only.

The LDEV's emulation type.

Capacity

The LDEV's capacity.

CLPR

The LDEV's CLPR ID.

Encryption

Encryption information.

  • Enabled: Encryption is enabled for the parity group to which the LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption enabled.

  • Disabled: Encryption is disabled for the parity group to which the LDEV belongs, or a V-VOL is associated with a pool in which a pool volume has encryption disabled.

  • Mixed: The pool to which the LDEV belongs contains both pool volumes for which encryption is enabled and ones for which encryption is disabled.

Note: Data encryption is not ensured in an LDEV with Mixed encryption status.

For DP-VOLs, the pool to which an LDEV belongs is an external volume or blocked.

For an external volume or migration volume, a hyphen (-) is displayed.

T10 PI (VSP Gx00 models and VSP Fx00 models)

The LDEV's T10 PI attribute.

  • Enabled: The T10 PI attribute is enabled.

  • Disabled: The T10 PI attribute is disabled.

Number of Secondary Volumes

The total number of S-VOLs assigned to the P-VOL. This value includes the volumes for pairs that you are creating, volumes in existing pairs. For an L1 pair, this value does not include the number of L2 S-VOLs.

Primary Volume (VSP G1000, G1500, and VSP F1500)

HTI only.

The P-VOL information.

Values:

  • LDEV ID: The P-VOL's LDEV identifier:

  • LDEV Name: The P-VOL's LDEV name

  • Port ID: Port name of the P-VOL LDEV's LUN path.

  • Host Group Name: Host group name of the P-VOL LDEV's LUN path.

  • LUN ID: LUN ID of the P-VOL LDEV's LUN path.

  • Emulation Type: The P-VOL's emulation type

  • Capacity: The P-VOL's capacity

  • CLPR: The P-VOL's CLPR ID.

Mirror Unit (VSP G1000, G1500, and VSP F1500)

HTI only.

The mirror unit number.

If you have not allocated an LDEV to the S-VOL for an existing pair, a hyphen (-) is displayed.

Pool Name (ID) (VSP G1000, G1500, and VSP F1500)

HTI only.

The pool name and identification number.