Create Pairs confirmation window
Selected Pairs table
|
Item |
Description |
|---|---|
|
Local Storage System |
Information about volumes in the accessed system.
TCz/TC/URz only.
If the attribute is not set, a hyphen (-) is displayed. TC and UR only.
Note: Encryption of data is not ensured in an LDEV with the Mixed encryption status. To manage data encryption, use an LDEV in which Encryption is Enabled or Disabled. For an external volume, a hyphen (-) is displayed. For V-VOLs of Dynamic Provisioning or Dynamic Provisioning for Mainframe, the pool to which the LDEV belongs is an external volume or blocked.
Note: Encryption of data is not ensured in an LDEV with the Mixed encryption status. To manage data encryption, use an LDEV in which Encryption is Enabled or Disabled. A hyphen (-) is displayed if the pool to which the journal volume belongs is an external volume, created by migration, or blocked.
(VSP G1000, G1500, and VSP F1500) A hyphen (-) is displayed if the emulation type is other than OPEN-V. |
|
Copy Type (VSP G1000, G1500, and VSP F1500) |
Type of pair:
|
|
Remote Storage System |
Information about volumes in the system connected to the system you accessed.
|
|
Path Group ID |
Path group identifier. Not shown for TCz. |
|
CTG ID |
UR only. Consistency group identifier. |
|
Fence Level |
TC or TCz only Whether the P-VOL can be written to when the pair is split due to error.
|
|
Initial Copy Type |
Pair creation operation type. |
|
Copy Pace |
TC or TCz only Number of tracks to be copied per remote I/O operation. |
|
Initial Copy Priority |
Scheduling order for the initial copy operation. The range is 1 to 256, and the default is 32. |
|
CFW Data (VSP G1000, G1500, and VSP F1500) |
TCz only. Whether CFW (DASD fast write) data is copied to the S-VOL.
This is displayed only for TCz pairs. |
|
DFW to Secondary Volume (VSP G1000, G1500, and VSP F1500) |
TCz only. Whether the primary system splits the pair when the secondary system cannot copy DFW data to the S-VOL
|
|
Host I/O Time Stamp Transfer (VSP G1000, G1500, and VSP F1500) |
TCz only. Whether the host I/O time stamp is transferred from P-VOL to S-VOL. |
|
Error Level |
UR or URz only. Whether to split all pairs in the mirror if a failure occurs during this operation:
|
|
CFW (VSP G1000, G1500, and VSP F1500) |
URz only. Whether to copy cache fast write (CFW) data to the S-VOL.
|