Tier relocation rules, restrictions, and guidelines

Rules

For details on rebalancing, see Rebalancing the usage level among parity groups.

Performance monitoring or tier relocation conditions

The status of data collection, fixed monitoring, and tier relocation operations are described in the following table. The latest fixed monitoring information is referenced when tiers are relocated.

Monitoring information or execution conditions

Status of data collection in progress

Status of fixed monitoring information used in tier relocation

Tier relocation operations

Solutions

Unallocated pages.

Pages are not monitored.

No monitoring information on pages.

Tiers of the pages are not relocated.

Unnecessary. After the pages are allocated, monitoring and relocation are performed automatically.

Zero data is discarded during data monitoring.

Monitoring on pages is reset.

Only monitoring information on pages is invalid.

Tiers of the pages are not relocated.

Unnecessary. After the pages are allocated, monitoring and relocation are performed automatically.

V-VOL settings do not allow tier relocation.

Volume is monitored.

Monitoring information on the volume is valid.

If the tier relocation setting is being disabled at the performance monitoring finish time, tiers of the volume are not relocated.

N/A

When V-VOLs are deleted

Volume is not monitored.

Only monitoring information on the volume is invalid.

Tier relocation of the volume is suspended.

N/A

When execution mode is changed to Manual from Auto or vice versa.

Suspended.

Monitoring information collected before suspension is valid.

Suspended.

Collect the monitoring information again if necessary.1

When the power switch is power ON or OFF.

Monitoring is suspended by powering OFF and is not resumed even after powering ON.1

Monitoring information collected during the previous cycle is continuously valid.

Tier relocation is suspended by powering OFF and is resumed after powering ON.

Collect the monitoring information again if necessary.1

  • When Volume Migration is performed.

  • When Quick Restore of ShadowImage is performed.

The monitoring information of the volume is not collected at the present moment. In the next monitoring period, the monitoring information will be collected.

Monitoring information is invalid and the volumes need to be monitored.

Tier relocation to volumes is suspended.

Collect the monitoring information again if necessary.1

S-VOL of the following products when the initial copy operation is performed:

  • TrueCopy

  • Global-active device

  • Universal Replicator

Monitoring information is collected continuously, but the monitoring of the volumes is reset.2

No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid.

Tier relocation to volumes is suspended.

Collect the monitoring information again if necessary.1

  • When the number of tiers increases by adding pool-VOLs.

  • When the pool-VOLs of the tiers are switched by adding pool-VOLs.3

  • When tier rank of the external LDEV is changed.

Continued.

Fixed monitoring information is invalid because the monitoring information was discarded. If monitoring is set to the continuous mode, weighted data calculated by using the monitoring information in past periods is also discarded.

Suspended.

Relocate tiers again.1

When pool-VOLs are deleted.

Continued.

Monitoring information is invalid temporarily. The monitoring information is calculated again after deleting of pool-VOLs.4

Deleting the pool-VOL stops the tier relocation. The process resumes after the pool-VOL is deleted.

N/A

When a cache is blocked.

Continued.

No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid.

Suspended.

After recovering the faulty area, relocate tiers again.1

When an LDEV is blocked. (Pool-VOL or V-VOL)

Continued.

No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid.

Suspended.

After recovering the faulty area, relocate tiers again.1

When the depletion threshold of the pool is nearly exceeded during relocation.

Continued.

No effect on the fixed monitoring information. The monitoring information collected during the previous cycle continues to be valid.

Suspended.

Add pool-VOLs, then collect monitoring information and relocate tiers again.1

When execution mode is Auto and the execution cycle ends during tier relocation.

At the end time of execution cycle, data monitoring stops.

The monitoring information collected before monitoring performance stops is valid.

Suspended.

Unnecessary. The relocation is performed automatically in the next cycle.

When execution mode is Manual and 7 days elapse after monitoring starts.

Suspended.

The monitoring information collected before suspension is valid.

Continued.

Collect the monitoring information again if necessary.1

Notes:

  1. The execution mode is Auto or the script is written in manual execution mode, information is monitored again and tiers are relocated automatically.

  1. All pages of the S-VOLs are not allocated, and the monitoring information of the volume is reset. After the page is allocated to the new page, the monitoring information is collected.

  1. Example: Pool-VOLs of SAS15K are added to the following Configuration 1

  • Configuration 1 (before change): Tier 1 is SSD, Tier 2 is SAS10K, and Tier 3 is SAS7.2K.

  • Configuration 2 (after change): Tier 1 is SSD, Tier 2 is SAS15K, and Tier 3 is SAS10K and SAS7.2K.

  1. The monitoring information status is changed from invalid (INV) to calculating (PND). After completion of calculating, the monitor information status is changed from calculating (PND) to valid (VAL).