Defining port attributes (VSP G1000, G1500, and VSP F1500)

Initiator and RCU target ports must be set up on the primary and secondary systems for TrueCopy command and data transfer.

Before you begin

Procedure

  1. In Hitachi Command Suite:

  1. On the Resources tab, click Storage Systems, and then expand All Storage Systems.

  1. Expand the target storage system.

  1. Click Ports/Host Groups/iSCSI Targets under the target system you selected.

In Device Manager - Storage Navigator:

  1. Click Storage Systems, and then expand the Storage Systems tree.

  1. In the Storage Systems tree, click Ports/Host Groups/iSCSI Targets.

  1. In the Ports/Host Groups/iSCSI Targets window, click the Ports tab, select the port to be changed, and click Edit Ports.

  1. In the Edit Ports window, select a Port Attribute: Initiator or RCU Target.

For all other settings, see the Provisioning Guide for Open Systems.

  1. Click Finish.

  1. In the Confirm window, review the settings and enter a task name in the Task Name box.

  1. Click Apply to save your settings.