Adding remote connections

You can configure the storage systems for TrueCopy by adding a remote connection from the primary to the secondary system. Adding the connection and setting up remote paths prepares the systems for TC commands and operations.

olh-caution.gif Do not add or delete a remote connection or add a remote path at the same time that the SCSI path definition function is in use.

Before you begin

olh-note.gif When using RAID Manager (including Raidcom), the VSP G1000 and G1500, and VSP F1500 serial number requires a prefix of "3".

Also, operations involving remote paths cannot be performed when changing the microcode or firmware. Make sure a microcode or firmware change completes before beginning operations involving remote paths.

Procedure

  1. In Hitachi Command Suite:

  1. On the Resources tab, expand the Storage Systems tree.

  1. Right-click the target storage system and click Remote Connections.

In Device Manager - Storage Navigator:

  1. Click Storage Systems, and then expand the Storage Systems tree.

  1. In the Storage Systems tree, click Replication > Remote Connections.

  1. In the Remote Connections window, click the Connections (To) tab.

  1. In the Connections (To) tab, click Add Remote Connection.

  1. In the Add Remote Connection window, select the Connection Type:

olh-note.gif When using virtual storage machine volumes, make sure to specify the physical serial number of the storage system, not the serial number of the virtual storage machine.

  1. In the Local Storage System box, for Local CU, select the CU number in a range from 00 to FE.

  1. In the Remote Storage System box, specify the following:

  1. For Model, select the storage system model and number. Select 7 for VSP G1000 and G1500, and VSP F1500, 6 for VSP, 5 for USP V/VM, 19 for HUS VM, and 18 for VSP Gx00 models and VSP Fx00 models.

HUS VM (19) and VSP Gx00 and VSP Fx00 (18) can be selected only when System is selected for Connection Type.

  1. For Serial Number, enter one of the following secondary system serial numbers.

- VSP G1000 and G1500, and VSP F1500: 1 to 99999 (5 digits)

- VSP or USP V/VM: 1 to 99999 (5 digits)

- HUS VM: 200001 to 265535 (6 digits)

- VSP Gx00 models and VSP Fx00 models: 400001 to 499999 (6 digits)

olh-note.gif When using virtual storage machine volumes, make sure to specify the serial number of the physical storage system, not the serial number of the virtual storage machine.

  1. In the Remote Paths box, specify the following:

  1. For Path Group ID, select the path group ID (00-FF). A storage system can have a maximum of 64 registered path group IDs.

  1. For Minimum Number of Paths, select the minimum number of paths between the secondary and primary system. If the number of paths drops below the minimum, the primary system splits the pair.

The range is 1-8, and the default is 1.

  1. In the path ports boxes, select the ports used by the remote path.

You can add more remote paths by clicking the Add Path button. See Configuring additional remote paths for more information.

  1. (VSP G1000, G1500, and VSP F1500) In Select Type, select the port type.

  1. (VSP G1000, G1500, and VSP F1500) Select the port to use for the local storage system and the remote storage system. If you selected iSCSI for the port type, enter the IP address and the TCP port number for the port of the remote storage system. To add a path, click Add Path. If necessary, you can add a path later in the Add Remote Paths window.

  1. Click Options to access additional settings, which are optional.

  1. For RIO MIH Time, enter an interval in seconds that, if exceeded, causes the data-transfer operation to be reported as failed by the system. The range is 10-100 seconds, and the default is 15. RIO MIH means "remote I/O missing interrupt handler".

  1. For Round Trip Time, enter a time limit for data copy from P-VOL to S-VOL in ms. The range is 1-500 ms, and the default is 1.

  1. Click Finish.

  1. In the Confirm window, review the settings and enter a task name in the Task Name box.

  1. Click Apply to save your settings.