Edit Mirror Options confirmation window

Item

Description

Journal ID

Journal identifier.

Mirror ID

Mirror identifier.

Journal Type (VSP G1000, G1500, and VSP F1500)

Journal copy type, UR or URMF.

Attribute

Whether the journal is Master, Restore, or Initial (registered but no pair volumes assigned).

Status

Mirror’s status.

Path Watch Time

Interval from the time a path becomes blocked to the time when the mirror is suspended.

(VSP Gx00 models and VSP Fx00 models) When the status of the mirror's secondary side (RCU) is Hold, Holding, or Hold(Failure), a hyphen (-) is displayed.

Path Watch Time Transfer (VSP G1000, G1500, and VSP F1500)

Indicates whether to assign the master journal’s Path Watch Time value to the restore journal. Yes or No.

Path Watch Time Transfer (VSP Gx00 models and VSP Fx00 models)

Indicates whether to transfer the master journal's Path Watch Time value to the mirror's secondary side (RCU). When transferred, the Path Watch Time values of the mirror's primary side (MCU) and the secondary side (RCU) will be consistent.

  • Yes: Path Watch Time value will be transferred to the mirror's secondary side (RCU).

  • No: Path Watch Time value will not be transferred to the mirror's secondary side (RCU).

Copy Pace

Pace for copying data during initial copy: Slower is the default, Medium, Faster.

If the selected journal is a restore journal, a hyphen is displayed.

Transfer Speed

Data transfer line speed in Mbps (megabits per second): 3, 10, 100, or 256.

Delta Resync Failure

Processing that takes place in the event of delta resync operation failure when using UR with TC: Entire Copy, No Copy.

(VSP G1000, G1500, and VSP F1500) When using UR with GAD, the operation is the same as for No Copy regardless of the settings. If delta resync fails, no processing will be performed and the S-VOL will not be updated. In the event of delta resync failure, you need to resync the UR pair.

Remote Storage System

Displays the following information about the system connected to the system you accessed:

  • Model/Serial Number: Storage system’s model and serial number. A hyphen displays if the mirror attribute is Initial.

  • Journal ID: Journal identifier. A hyphen displays if the mirror attribute is Initial.

Path Group ID

Path group identifier specified at DKC registration.

Number of Data VOLs

Number of volumes associated with the journal.

(VSP G1000, G1500, and VSP F1500) If the journal uses multiple mirror IDs, volumes in mirrors with Hold, Holding, or Hold(Failure) status are not included.

(VSP Gx00 models and VSP Fx00 models) With the delta resync configuration, the number of data volumes registered to the journal of the mirrors not for delta resync is displayed. The number of volumes registered to the journal of the delta resync mirrors (whose status is Hold, Holding, or Hold(Failure)) is not displayed.

Data Capacity

Total capacity of all the associated volumes.

(VSP G1000, G1500, and VSP F1500) If the journal uses multiple mirror IDs, volumes in mirrors with Hold, Holding, or Hold(Failure) status are not included.

(VSP Gx00 models and VSP Fx00 models) With the delta resync configuration, the total capacity of the data volumes registered to the journal of the mirrors not for delta resync is displayed. The total capacity of the data volumes registered to the journal of the delta resync mirrors (whose status is Hold, Holding, or Hold(Failure)) is not displayed.

Remote Command Device

LDEV number of the remote command device if it is assigned to the mirror.

  • The column is blank if the remote command device is not assigned to the mirror.

  • A hyphen (-) indicates the remote command device cannot be assigned to the mirror.