Adding trap notification for SNMP v1 and v2c

Follow this procedure to procedure to add IP addresses and communities to trap notification for SNMP versions v1 and v2c.

Before you begin

You must have the Storage Administrator (Initial Configuration) role to perform this task.

For more information, see the Add Sending Trap Setting window in the Hitachi Device Manager - Storage Navigator User Guide .

Procedure

  1. Navigate to the Alert Notifications window in the Maintenance Utility.

In Hitachi Command Suite:

  1. On the Resources tab, click Storage Systems, and then expand the Storage Systems tree.

  1. Expand the target storage system, and then select Maintenance Utility.

  1. In the Maintenance Utility window, select Administration > Alert Notifications.

In Device Manager - Storage Navigator:

  1. Display the Device Manager - Storage Navigator main window.

  1. From the Maintenance Utility menu, select Alert Notifications.

  1. In the Alert Notifications window, click Set Up.

  1. In the Set Up Alert Notifications window, select the SNMP tab.

  1. Under SNMP Agent, click Enable.

  1. Under SNMP Version, select v1 or v2c.

  1. Under Registered Sending Trap Settings, click Add.

  1. In the Add Sending Trap Setting window, under Community, complete one of the following:

You can enter up to 180 letters, numbers, and symbols, except the following:

" \ ; : , * ? < > | / ^ & % '

Do not use a space at the beginning or end of the name.

  1. Under Send Trap To, complete the following:

olh-note.gif Any IP address that has all values set to zero (0) cannot be specified for IPv4 and IPv6. The IPv6 address is specified by entering eight hexadecimal numbers that are separated by colons (:) using a maximum of 4 digits from zero (0) to FFFF inclusive. The default form of the IPv6 address can be specified.

  1. Click OK.

The IP address and community you entered are added to the Registered Sending Trap Settings table.

  1. Confirm the settings, and then click Apply.