Pair operations
The following table lists the UR pair operations and provides the corresponding RAID Manager commands.
|
Operation |
Options |
In HDvM - SN? |
RAID Manager command and options |
|
|---|---|---|---|---|
|
Create UR Pairs |
Copy Type (VSP G1000, G1500, and VSP F1500) |
Yes |
paircreate None |
|
|
LU Selection |
Yes |
paircreate None1 |
||
|
Base Secondary Volume |
Yes |
paircreate None2 |
||
|
Mirror Selection |
Yes |
paircreate None1 |
||
|
CTG ID |
Yes |
paircreate -f[g] fence [CTG ID] |
||
|
Initial Copy Type |
Yes |
paircreate [-nocopy | -nocsus] |
||
|
Initial Copy Priority |
Yes |
paircreate None |
||
|
Error Level |
Yes |
paircreate -nomsg |
||
|
Split Pairs |
Secondary Volume Write |
Yes |
pairsplit -rw |
|
|
Split Mirrors |
Secondary Volume Write |
Yes |
None |
|
|
Split Mode |
Yes |
None |
||
|
Resync Pairs |
Copy Priority |
Yes |
pairresync None |
|
|
Error Level |
Yes |
pairresync -nomsg |
||
|
Resync Mirrors |
None |
Yes |
None |
|
|
Delete Pairs (VSP G1000, G1500, and VSP F1500) |
None |
Yes |
pairsplit -S |
|
|
Delete Mirrors |
Delete Mode |
Yes |
None |
|
|
(VSP G1000, G1500, and VSP F1500) Notes:
|
||||