UR PSUS types and behaviors

The PSUS status, which indicates that a pair is split or suspended, can be set by the user or by the system from the primary or secondary storage system. The following table lists and describes the PSUS status types.

PSUS type

Applies to

Description

S-VOL by Operator

P-VOL, S-VOL

  • The user split the pair from the primary or secondary storage system using the S-VOL-write option.

  • RAID Manager displays this PSUS type as SSWS.

By MCU

S-VOL

  • The secondary storage system received a request from the primary storage system to split the pair.

  • The P-VOL PSUS type is S-VOL by Operator.

  • RAID Manager displays this PSUS type as SSWS.

By RCU

P-VOL, S-VOL

  • The primary storage system suspended the pair after detecting an error condition on the secondary storage system.

  • The S-VOL suspend type is S-VOL Failure.

  • RAID Manager displays this suspend type as PSUE.

Pairsplit-S to RCU

P-VOL

  • The primary storage system detected that the S-VOL is unpaired after the user released the pair from the secondary storage system.

  • The pair cannot be resynchronized.

JNL Cache Overflow

P-VOL, S-VOL

  • The pair was suspended because the journal volume was near capacity.

  • RAID Manager displays this PSUS type as SSWS.

S-VOL consistency statuses

Consistency status

Description

Volume

  • Only the current pair was split or suspended.

  • Update sequence consistency between this S-VOL and other S-VOLs in the associated journal is not ensured.

  • This S-VOL cannot be used for disaster recovery at the secondary site.

  • This status is indicated when:

  • The pair is split by the user using the Split Pairs window (Suspend Range-Volume (LU) pairsplit option).

  • The pair is suspended due to a failure that did not affect the entire journal.

Mirror

  • The pair was split or suspended along with the other pairs in the associated mirror.

  • Update sequence consistency between this S-VOL and other S-VOLs in this mirror is ensured.

  • This S-VOL can be used for disaster recovery on the secondary storage system.

  • This status is indicated when:

  • The mirror is split using the Split Mirrors window (or by specifying mirror of the RAID Manager pairsplit -r option).

  • All pairs in the associated mirror are suspended due to a failure that affected the entire group, for example, path failure.

  • One pair in the mirror was suspended due to a failure that did not affect the entire group.