Edit Journal Options window

Use this window to change journal options.

For instructions, in the Help Contents tab, click: Maintaining the UR system > Journal and mirror maintenance > Changing options used by journals

Item

Description

Inflow Control

Whether flow of update data to the journal volume is restricted by slowing the response to hosts.

Data Overflow Watch

Number of seconds the system will monitor metadata and journal data to the journal volume when the journal volume is full (100%). The field is blank if Inflow Control is disabled. When the metadata area or journal data area are full and no more data can be stored, the system regards this as a error and suspends the pairs in the journal.

The range is between 0 and 600, and the default is the value set when the journal was created.

In a 3DC multi-target configuration in which three UR sites are combined, if the status of the two mirrors in the primary site is Active and the free space in the journal data area or metadata area is less than a certain amount, one of the mirrors in the journal will be suspended by error, regardless of the value in Data Overflow Watch.

Cache Mode

Indicates whether journal data is stored in cache memory on the restore journal.

  • Enable: Journal data is stored in cache memory. When the available cache memory becomes insufficient, the journal data is also stored in a journal volume.

  • Disable: Journal data is stored in a journal volume instead of cache memory. This setting is disabled in the master journal. However, this setting is enabled if you use the horctakeover command of RAID Manager (for Universal Replicator) or the YKRESYNC REVERSE command of Business Continuity Manager (for Universal Replicator for Mainframe) to change the master journal to the restore journal.

Timer Type (VSP G1000, G1500, and VSP F1500)

UR-MF only.

Type of clock used for consistency time. Must be the same for primary and secondary storage systems.