View Pair Synchronization Rate window
This window includes the Pairs table.
Pairs table
The following table lists the items in this table on the View Pair Synchronization Rate window.
|
Item |
Description |
|---|---|
|
Primary Volume |
The P-VOL information. Values:
|
|
Copy Type |
The SI volume’s copy type. Values:
|
|
Snapshot Group |
The HTI snapshot group name. If you have not configured a snapshot group for the HTI pair, this item is blank. |
|
Status |
The pair status. |
|
Synchronization Rate (%) |
For SI
SIz:
For Thin Image pairs where the cascade attribute is disabled, the rate at which the Thin Image S-VOL matches the next new generation of the S-VOL. If the S-VOL is the latest one, the storage system computes the synchronization rate by comparing the S-VOL with the P-VOL. For Thin Image pairs where the cascade attribute is enabled, the following information is displayed depending on the pair status:
|
|
Secondary Volume |
The S-VOL information. Values:
|
|
Mirror Unit |
The mirror unit number. |
|
Cascade (VSP G1000, G1500, and VSP F1500) |
Indicates whether a cascaded pair can be created
A hyphen (-) is displayed for non-HTI pairs. |
|
Type (VSP G1000, G1500, and VSP F1500) |
The pair type.
A hyphen (-) is displayed for non-HTI pairs. |
|
Topology ID (VSP G1000, G1500, and VSP F1500) |
The topology ID, which indicates the layer of the pair based on the mirror unit. The topology ID consists of the LDEV ID of the volume (root volume for Thin Image pairs) and the mirror unit number. |
|
Refresh button |
Click to update the information in this table. |