ENTITYTRAP/1/ENTITYBRDTEMPALARM:OID [OID] Temperature rise over or fall below the warning alarm threshold.(Index=[INTEGER],EntryPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER],EntityThresholdValue=[INTEGER],EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])
The temperature exceeds the upper threshold or falls below the lower threshold. (You can run the display temperature command to view the alarm threshold.)
| Alarm ID | Alarm Severity | Alarm Type |
|---|---|---|
1.3.6.1.4.1.2011.5.25.219.2.10.13 |
Critical |
environmentalAlarm (6) |
| Name | Meaning |
|---|---|
OID |
Indicates the ID of a MIB object. |
Index |
Indicates the index of a temperature sensor. |
EntryPhysicalIndex |
Indicates the sub-index of an entity. |
PhysicalName |
Indicates the entity name. |
EntityThresholdType
|
Indicates the alarm type. |
EntityThresholdValue |
Indicates the alarm threshold. |
EntityThresholdCurrent |
Indicates the current temperature. |
EntityTrapFaultID |
Indicates the alarm reason ID. |
Cause 1: The device is not ventilated well (for example, the air filter is blocked), which causes heat unable to be dissipated.
Cause 2: The ambient temperature is high.
No fan is available on the AC6508, AC6507S, or AirEngine 9700S-S. Check the fans in the chassis or the ambient temperature.