ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid

Description

ENTITYTRAP/4/BOARDINVALID: OID [oid] Board is invalid for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=132624, EntityTrapReasonDescr="[OCTET]")

The board fails.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.219.2.2.5

Warning

equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the ID of the MIB object.

Index

Indicates the entity index.

EntityPhysicalIndex

Indicates the physical entity index.

EntPhysicalName

Indicates the name of the physical entity.

EntityTrapEntType

Indicates the type of the physical entity, such as mpu(1), and lpu(2).

EntityTrapFaultID

Indicates the error code.

EntityTrapReasonDescr

Indicates the description of the alarm cause.

Impact on the System

Services will be interrupted.

Possible Causes

Error Code

Possible Cause

132629

The PHY chip is abnormal.

132624

The ECC detects a memory error.

132614

The logic of the CPLD on the card is abnormal.

132616

The CPLD clock is faulty.

132148

The optical module is abnormal.

132622

The clock driver IIC is faulty.

Procedure

  1. Check whether the faulty board is registered successfully and services are running properly.

    Run the display device command to check whether the faulty board is registered successfully, and run the display interface command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.

    • If the faulty board is registered successfully and services are running properly, no action is required.
    • If the faulty board is unregistered or services are not running properly, go to step 2.

  2. If the faulty board is a main control board, run the reboot command to reboot the device. Then check whether the device is working properly.

    • If the board can be registered successfully and services are running properly, no action is required.
    • If the board cannot be registered or services cannot run properly, the board hardware is faulty. Replace this board.
    • If the fault persists, go to step 3.

  3. Contact technical support personnel.