ERRDOWN_1.3.6.1.4.1.2011.5.25.257.2.1 hwErrordown

Description

ERRDOWN/4/ErrordownOccur: OID [oid] Error-down occurred. (Ifindex=[INTEGER], Ifname=[STRING], Cause=[STRING])

The alarm was generated when an errordown event occurred.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.257.2.1

Warning

communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

IfIndex

Index of an interface

Ifname

Interface name

Cause

Cause of the errordown event

Impact on the System

After the errordown event occurs, traffic cannot be forwarded on relevant interfaces and services are interrupted.

Possible Causes

The faults detected by service modules triggered errordown events. The possible causes are as follows:

Procedure

  1. Locate the fault based on the value of the Cause field in the alarm.

  2. Check whether the interface is specified as an edge port.

    • If the interface is not specified as an edge port, go to Step 3.

    • If the interface is specified as an edge port, go to Step 4.

  3. Perform the following steps.

    • Run:

      interface interface-type interface-num

      The interface view is displayed.

    • Run:

      undo stp edged-port and undo shutdown

      The edge port configuration is removed. Check whether the log still exists. If the log still exists, go to Step 4.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
Copyright © Huawei Technologies Co., Ltd.
Next topic >