ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.3 hwOpticalFail

Description

ENTITYTRAP/2/OPTICALFAIL: OID [oid] Optical Module become failure.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])

Optical module detection failed.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.219.2.4.3

Major

equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

Index

Indicates an index.

EntityPhysicalIndex

Indicates a physical index.

PhysicalName

Indicates the entity name.

EntityTrapFaultID

Indicates the error code.

Impact on the System

The interface that has the optical module installed may fail to go Up.

Possible Causes

Cause 1:

No cable or optical module was detected.

Cause 2:

The cable type was detected but the specific type cannot be identified. For example, whether the cable is active is passive and the cable length cannot be identified.

Cause 3:

The cable does not comply with interface specifications.

Procedure

  1. Run the display transceiver interface interface-type interface-number command to check whether Transceiver Type matches the interface type. For example, a GE interface needs to use an optical module that provides the GE rate.

    • If so, go to step 2.
    • If not, replace the optical module with one that matches the interface type.

  2. Check whether the optical module is a Huawei-certified switch one.

    • If so, collect alarm information and configuration information, and then contact technical support personnel.
    • If not, replace the optical module with a Huawei-certified switch one.

Copyright © Huawei Technologies Co., Ltd.