RMON_1.3.6.1.4.1.2011.1.3.4.0.1 pririsingAlarm

Description

RMON/3/RISING:OID [OID] Private alarm table [alram-line-index] monitors [description] with sample type [sample-type], has sampled alarm value [alarm-value] uprise [alarm-upper-limit].

The value of the alarm entity was higher than prialarmFallingThreshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.1.3.4.0.1

Minor

communicationsAlarm(2)

Parameters

Name Meaning

OID

Indicates the OID of the alarm.

alarm-line-index

Indicates the index of the alarm entry.

description

Indicates the description of the alarm entry

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

alarm-upper-limit

Indicates the upper threshold of the alarm.

Impact on the System

None.

Possible Causes

This alarm occurred in the NQA test.

Cause 1: If the current sampled value was greater than or equal to this threshold, and the last sampled value was smaller than this threshold, the alarm was generated.

Cause 2: When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and prialarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.

Procedure

  • This trap message is informational only, and no action is required.

Related Information

None.