RMON_1.3.6.1.4.1.2011.1.3.4.0.2 prifallingAlarm

Description

RMON/3/FALLING:OID [oid] Private alarm table [alram-line-index] monitors [description] with sample type [sample-type], has sampled alarm value [alarm-value] less than or equal to [alarm-upper-limit].

The value of the alarm entity was lower than prialarmFallingThreshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.1.3.4.0.2

Minor

communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the OID of the alarm.

alram-line-index

Indicates the index of the alarm entry.

description

Indicates the description of the alarm entry.

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

alarm-upper-limit

Indicates the lower threshold of the alarm.

Impact on the System

System will not be affected.

Possible Causes

This alarm occurred in the NQA test.

Cause 1: If the current sampled value was smaller than or equal to this threshold, and the last sampled value was greater than this threshold, the alarm was generated.

Cause 2: After this alarm entry became valid, when the first sampled value was smaller than or equal to this threshold, and the values of fallingAlarm, risingAlarm, and risingOrFallingAlarm were equal, the alarm was generated.

Procedure

  • This trap message is informational only, and no action is required.

Related Information

None.