ENTITYTRAP/1/ENTITYBRDTEMPALARM:OID [OID] Temperature rise over or fall below the warning alarm threshold.(Index=[INTEGER],EntryPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER],EntityThresholdValue=[INTEGER],EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])
The temperature exceeds the upper threshold or falls below the lower threshold. (You can run the display temperature command to view the alarm threshold.)
| Alarm ID | Alarm Severity | Alarm Type |
|---|---|---|
| 1.3.6.1.4.1.2011.5.25.219.2.10.13 | Critical | environmentalAlarm (6) |
| Name | Meaning |
|---|---|
| OID | Indicates the ID of a MIB object. |
| Index | Indicates the index of a temperature sensor. |
| EntryPhysicalIndex | Indicates the sub-index of an entity. |
| PhysicalName | Indicates the entity name. |
EntityThresholdType
|
Indicates the alarm type. |
| EntityThresholdValue | Indicates the alarm threshold. |
| EntityThresholdCurrent | Indicates the current temperature. |
| EntityTrapFaultID | Indicates the alarm reason ID. |
Cause 1: The device is not ventilated well (for example, the air filter is blocked), which causes heat unable to be dissipated.
Cause 2: The ambient temperature is high.
The AC6508, AC6507S, AirEngine9700S-S, and ACU2 do not have a fan. Check the chassis fans or environment temperature.