ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.10.15 hwBrdTempFatalAlarm

Description

ENTITYTRAP/1/ENTITYBRDTEMP_FATALALARM:OID [OID] Temperature rise over or fall below the critical alarm threshold.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER],EntityThresholdValue=[INTEGER],EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])

The board overheats. The fan may be faulty.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.10.15 Critical environmentalAlarm (6)

Parameters

Name Meaning
OID Indicates the MIB object ID.
Index Indicates the entity index.
EntryPhysicalIndex Indicates the entity physical index.
PhysicalName Indicates the entity name.
EntityThresholdType Indicates the alarm type.
EntityThresholdValue Indicates the alarm threshold.
EntityThresholdCurrent Indicates the current temperature.
EntityTrapFaultID Indicates the ID of alarm cause.

Impact on the System

When temperature exceeds the threshold, boards may be faulty. Board failures will cause service interruption.

Possible Causes

The fan is faulty.
NOTE:

The AC6508, AC6507S, AirEngine9700S-S, and ACU2 do not have a fan. Check the chassis fans or environment temperature.

Procedure

  1. Run the display temperature command to view the current temperature and upper and lower alarm thresholds. Ensure that the upper and lower thresholds are set properly.
  2. Run the display fan command to check whether the fan is operating properly. If not, repair or replace the fan.

Related Information

None.