ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.15.1 hwMemUtilizationRising

Description

ENTITYTRAP/2/MEMORYUSAGERISING: OID [oid] MEMORY utilization exceeded the pre-alarm threshold.(Index=[INTEGER], HwEntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdWarning=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])

The memory usage of the system exceeds the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.15.1 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
Index Indicates the entity index.
HwEntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the physical entity name.
EntityThresholdType Indicates the threshold type.
EntityThresholdWarning Indicates the alarm threshold.
EntityThresholdCurrent Indicates the current value.
EntityTrapFaultID Indicates the error code.

Impact on the System

If the threshold is not high (for example, 50% or 60%), services are not affected. If the threshold is high (for example 80%), it may have the following impacts.
  • Services cannot be allocated with memory and become unavailable.
  • The storage medium has insufficient space, affecting log functions and software upgrades.

Possible Causes

Cause 1: The memory alarm threshold is low.

Cause 2: The device provides too many services.

Cause 3: The device memory leaks.

Procedure

  1. Run the display memory-usage command to check the alarm threshold for memory usage. Check whether the alarm threshold is set properly.
    1. If so, go to 3.
    2. If not, go to 2.
  2. Run the set memory-usage threshold command to set a proper alarm threshold for memory usage. After that, check whether the alarm persists.
    1. If so, go to 3.
    2. If not, go to 5.
  3. Delete unnecessary services and configurations to reduce memory usage.
    1. If this alarm persists, go to 4.
    2. If the alarm is cleared, go to 5.
  4. Collect alarms, logs, and configurations, and then contact technical support personnel.
  5. If the alarm is cleared, no further action is required.

Related Information


Copyright © Huawei Technologies Co., Ltd.