ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail

Description

ENTITYTRAP/2/BOARDFAIL: OID [oid] Board become failure for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

Some functions on the board are invalid.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.2.3 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
Index Indicates the entity index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the name of the physical entity.
EntityTrapEntType Indicates the type of the physical entity, such as mpu(1), and lpu(2).
EntityTrapFaultID Indicates the error code.
EntityTrapReasonDescr Indicates the description of the alarm cause.

Impact on the System

The board is unavailable or some services are interrupted.

Possible Causes

Error Code

Possible Cause

132865

The RTC was abnormal.
NOTE:
When the RTC is faulty, the system time may be incorrect after the device is restarted. However, services indifferent to system timing are not affected. If a NTP server is available on the network, the system time will be corrected after you enable the NTP client function on the device.

2125827

The temperature sensor is abnormal.

132121

The current on the USB flash drive exceeds the upper limit.

132149 The bad block rate for the NAND flash exceeds the threshold.
132616 The CPLD clock is faulty.
132618 The NP chip is faulty.

Procedure

  1. Check whether the faulty board is registered successfully and services are running properly.

    Run the display device command to check whether the faulty board is registered successfully, and run the display interface command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.

    • If the faulty board is registered successfully and services are running properly, no action is required.
    • If the faulty board is unregistered or services are not running properly, go to step 2.

  2. If the faulty board is a main control board, run the reboot command to reboot the device. Then check whether the device is working properly.

    • If the board can be registered successfully and services are running properly, no action is required.
    • If the board cannot be registered or services cannot run properly, the board hardware is faulty. Replace this board.
    • If the fault persists, go to step 3.

  3. Contact technical support personnel.

Related Information


Copyright © Huawei Technologies Co., Ltd.