ENTITYTRAP/4/BOARDFAILRESUME: OID [oid] Board resume from failure.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER])
Functions on the board are restored.
| Alarm ID | Alarm Severity | Alarm Type |
|---|---|---|
| 1.3.6.1.4.1.2011.5.25.219.2.2.4 | Warning | equipmentAlarm(5) |
| Name | Meaning |
|---|---|
| OID | Indicates the ID of the MIB object. |
| Index | Indicates the entity index. |
| EntityPhysicalIndex | Indicates the physical entity index. |
| EntPhysicalName | Indicates the name of the physical entity. |
| EntityTrapEntType | Indicates the type of the physical entity, such as mpu(1), and lpu(2). |
| EntityTrapFaultID | Indicates the error code. |
Error Code |
Possible Cause |
|---|---|
132865 |
The RTC returns to the normal status. |
132614 |
The CPLD returns to the normal status. |
132629 |
The PHY returns to the normal status. |
2125827 |
The temperature sensor returns to the normal status. |
132624 |
The ECC detects that the memory fault is rectified. |
132121 |
The USB recovers from current overload. |