ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.5.1 hwPowerRemove

Description

ENTITYTRAP/4/POWERREMOVE: OID [oid] Power has been removed.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])

The power supply unit was removed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.5.1 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the physical entity name.
EntityTrapFaultID Indicates the error code.

Impact on the System

Boards cannot be powered on because power is insufficient.

Possible Causes

The power supply unit was removed.

Procedure

  1. Check whether the power supply unit was removed manually.

    • If so, no action is required.
    • If not, reinstall the power supply unit and go to step 2.

  2. Run the display power command to check whether the power supply unit is present.

    • If so, replace the power supply unit.
    • If not, go to step 4.

  3. End.
  4. Contact technical support personnel.

Related Information