ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.5.3 hwPowerFail

Description

ENTITYTRAP/3/TRAPID_ENTITY_POWER_FAIL:OID [oid] Power become failure.(EntityPhysicalIndex=[INTEGER], PhysicalName=\"[OCTET]\",EntityTrapFaultID=[INTEGER], EntityOperStatus=[INTEGER],EntityTrapReasonDescr=\"[OCTET]\")

The power supply may fail.

NOTE:

This alarm is supported only by the AC6805.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.5.3 Minor equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
EntityPhysicalIndex Indicates the index of the physical entity.
PhysicalName Indicates the physical entity name.
EntityTrapFaultID Indicates the error code.
EntityOperStatus Indicates the faulty status.
EntityTrapReasonDescr Indicates the description of the alarm cause.

Impact on the System

The device may fail to run properly.

Possible Causes

Error Code

Possible Cause

136961 Failed to obtain voltage information from the I2C interface.
136962 Overvoltage occurs.
136963 Undervoltage occurs.

Procedure

  1. Change the power supply and check whether the alarm persists.

    • If so, go to Step 2.
    • If not, go to Step 3.

  2. Collect alarms, logs, and configurations, and then contact technical support personnel.
  3. End.