ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.6.1 hwFanRemove

Description

ENTITYTRAP/4/FANINSERT:OID [OID] Fan has been removed.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])

This alarm is generated when a fan module is removed.

NOTE:

Only the AC6805 supports this alarm.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.6.1 Warning equipmentAlarm (5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the resource ID of an entity.
Entity physical index Indicates the sub-index of an entity.
Physical name Indicates the name of an entity.
Entity Trap Fault ID Indicates the cause ID of the alarm.

Impact on the System

The temperature of boards becomes high.

Possible Causes

The fan is removed.

Procedure

  • Run the display fan command to check whether the fan is working properly. If not, remove and install the fan tray to ensure that it is well connected. If the fault persists, contact technical support personnel.