POE_1.3.6.1.4.1.2011.5.25.195.40.11 hwPoePdClassOvercurrent

Description

POE/4/PDCLASSOVERCURRENT: OID [oid] has detected a classfication overcurrent PD and power denied.(IfIndex=[INTEGER], Interface="[OCTET]")

The system detects that overcurrent occurs during PD classification and does not provide power for PDs.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.195.40.11 Warning communicationsAlarm(2)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
IfIndex Indicates the interface index.
Interface Indicates the interface name.

Impact on the System

Services are not affected.

Possible Causes

The PD does not comply with standards.

Procedure

  1. You can run the poe high-inrush enable slot slot-id command in the system view to configure an interface to allow generation of the high pulse current. Then check whether the alarm is cleared.

    • If yes, go to step 4.
    • If not, go to step 2.

  2. Replace the PD and check whether the alarm is cleared.

    • If yes, go to step 4.
    • If not, go to step 3.

  3. Contact technical support personnel.
  4. End.

Related Information

None