RMON/3/RISING:OID [OID] Private alarm table [alram-line-index] monitors [description] with sample type [sample-type], has sampled alarm value [alarm-value] uprise [alarm-upper-limit].
The value of the alarm entity was higher than prialarmFallingThreshold.
| Alarm ID | Alarm Severity | Alarm Type |
|---|---|---|
| 1.3.6.1.4.1.2011.1.3.4.0.1 | Minor | communicationsAlarm(2) |
| Name | Meaning |
|---|---|
| OID | Indicates the OID of the alarm. |
| alarm-line-index | Indicates the index of the alarm entry. |
| description | Indicates the description of the alarm entry |
| sample-type | Indicates the type of the sampled alarm. |
| alarm-value | Indicates the alarm value. |
| alarm-upper-limit | Indicates the upper threshold of the alarm. |
This alarm occured in the NQA test.
Cause 1: If the current sampled value was greater than or equal to this threshold, and the last sampled value was smaller than this threshold, the alarm was generated.
Cause 2: When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and prialarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.