ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.5.3 hwPowerFail

Description

ENTITYTRAP/3/TRAPID_ENTITY_POWER_FAIL:OID [oid] Power become failure.(EntityPhysicalIndex=[INTEGER], PhysicalName=\"[OCTET]\",EntityTrapFaultID=[INTEGER], EntityOperStatus=[INTEGER],EntityTrapReasonDescr=\"[OCTET]\")

The power supply may fail.

This alarm is supported only by the AC6805, AirEngine 9700-M1, and AirEngine 9700-M.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.219.2.5.3

Minor

equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the ID of a MIB object.

EntityPhysicalIndex

Indicates the index of the physical entity.

PhysicalName

Indicates the physical entity name.

EntityTrapFaultID

Indicates the error code.

EntityOperStatus

Indicates the faulty status.

EntityTrapReasonDescr

Indicates the description of the alarm cause.

Impact on the System

The device may fail to run properly.

Possible Causes

Error Code

Possible Cause

136961

Failed to obtain voltage information from the I2C interface.

136962

Overvoltage occurs.

136963

Undervoltage occurs.

Procedure

  1. Change the power supply and check whether the alarm persists.

    • If so, go to Step 2.
    • If not, go to Step 3.

  2. Collect alarms, logs, and configurations, and then contact technical support personnel.
  3. End.