ERRDOWN/4/ErrordownOccur: OID [oid] Error-down occurred. (Ifindex=[INTEGER], Ifname=[STRING], Cause=[STRING])
The alarm was generated when an errordown event occurred.
| Alarm ID | Alarm Severity | Alarm Type |
|---|---|---|
1.3.6.1.4.1.2011.5.25.257.2.1 |
Warning |
communicationsAlarm(2) |
| Name | Meaning |
|---|---|
oid |
Indicates the MIB object ID of the alarm. |
IfIndex |
Index of an interface |
Ifname |
Interface name |
Cause |
Cause of the errordown event |
After the errordown event occurs, traffic cannot be forwarded on relevant interfaces and services are interrupted.
If the value of the Cause field is bpdu-protection, go to Step 2.
If the value of the Cause field is efm-threshold-event, rectify the fault according to the log EFM_1.3.6.1.4.1.2011.5.25.136.1.6.4 hwDot3ahEfmThresholdEvent.
If the value of the Cause field is efm-remote-failure, rectify the fault according to the log EFM_1.3.6.1.4.1.2011.5.25.136.1.6.5 hwDot3ahEfmNonThresholdEvent.
interface interface-type interface-num
The interface view is displayed.
undo stp edged-port and undo shutdown
The edge port configuration is removed. Check whether the log still exists. If the log still exists, go to Step 4.