PM_1.3.6.1.4.1.2011.5.25.190.1.9.1 hwPMStatisticsTaskThresholdTriggerAlarm

Description

PM/4/hwPMStatisticsTaskThresholdTriggerAlarm: OID [OID] The statistics value exceeded the threshold. (StatisticsTaskName=[OCTET], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsObjectName=[OCTET], StatisticsTaskName=[OCTET], StatisticsObjectType=[GA UGE], StatisticsIndicatorID=[GAUGE], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsIndicatorID=[GAUGE], TriggerType=[integer], StatisticsCycle=[integer], TriggerHighValue=[GAUGE], TriggerLowValue=[GAUGE], CurrentHighValue=[GAUGE], CurrentLowValue=[GAUGE])

Performance statistics exceeded the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.190.1.9.1 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
OID ID of a MIB object
StatisticsTaskName Name of a performance statistics task
StatisticsObjectType Type of a performance statistics object
StatisticsObjectName Name of a performance statistics object
StatisticsIndicatorID Indicator ID of a performance statistics task
TriggerType Type of threshold rules for performance statistics tasks
StatisticsCycle Interval for collecting performance statistics
TriggerHighValue The leftmost 32 bits of the threshold when the alarm is triggered
TriggerLowValue The rightmost 32 bits of the threshold when the alarm is triggered
CurrentHighValue The leftmost 32 bits of the current performance statistics data
CurrentLowValue The rightmost 32 bits of the current performance statistics data

Impact on the System

The threshold alarm indicates that the operating status of monitored objects may be abnormal.

Possible Causes

Statistics on performance indicators of monitored objects meet the rules for triggering the threshold alarm.

Procedure

  1. View the alarm information, analyze the operating status of corresponding alarm services, and restores monitored objects to the normal state.

Related Information

None