PM_1.3.6.1.4.1.2011.5.25.190.1.9.2 hwPMStatisticsTaskThresholdClearAlarm

Description

PM/6/hwPMStatisticsTaskThresholdClearAlarm: OID [OID] The threshold alarm is cleared. (StatisticsTaskName=[OCTET], StatisticsTaskName=[O CTET], StatisticsObjectType=[GAUGE], StatisticsObjectName=[OCTET], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsIndicatorID=[GAUGE], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsIndicatorID=[GAUGE], TriggerType=[integer], StatisticsCycle=[integer], ResumeHighValue=[GAUGE], ResumeLowValue=[GAUGE], CurrentHighValue=[GAUGE], CurrentLowValue=[GAUGE])

The threshold alarm is cleared.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.190.1.9.2

Cleared

qualityOfServiceAlarm(3)

Parameters

Name Meaning

OID

ID of a MIB object

StatisticsTaskName

Name of a performance statistics task

StatisticsObjectType

Type of a performance statistics object

StatisticsObjectName

Name of a performance statistics object

StatisticsIndicatorID

ID of a performance statistics task

TriggerType

Type of threshold rules for performance statistics tasks

StatisticsCycle

Interval for collecting performance statistics

ResumeHighValue

Leftmost 32 bits of the threshold when the alarm is cleared

ResumeLowValue

Rightmost 32 bits of the threshold when the alarm is cleared

CurrentHighValue

Leftmost 32 bits of the current performance statistics data

CurrentLowValue

Rightmost 32 bits of the current performance statistics data

Impact on the System

The alarm indicates that services are recovered.

Possible Causes

A threshold alarm is generated when KPI values of the monitored object become abnormal. When KPI values restore to the normal range, a clear alarm is generated.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None