RMON_1.3.6.1.2.1.16.0.1 risingAlarm

Description

RMON/4/ALARMUP: OID [OID] Alarm table [alarm-table-index] monitors [sample-object-oid] with sample type [sample-type], has sampled alarm value [alarm-value] uprise [rising-value].

The value of the alarm entity was higher than uprise.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.2.1.16.0.1 Warning environmentalAlarm(6)

Parameters

Name Meaning
OID Indicates the OID of the alarm.
alarm-table-index Indicates the index of the alarm entry.
sample-object-oid Indicates the OID of the sampled object.
sample-type Indicates the type of the sampled alarm.
alarm value Indicates the alarm value.
rising-value Indicates the upper threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1: If the current sampled value was greater than or equal to this threshold, and the last sampled value was smaller than this threshold, the alarm was generated.

Cause 2: When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and alarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.

Procedure

  • This trap message is informational only, and no action is required.

Related Information

None.

Copyright © Huawei Technologies Co., Ltd.
Next topic >